Download Commodity
If you've tried the furnace reset button, checked to make sure there is fuel oil and your furnace still won't showtime, don't fret. Earlier you phone call the repairman or start shopping for a new furnace, cheque the fuel source and make certain the line to the furnace is void of air. Running low on or being out of fuel tin can cause a furnace to non restart even later on yous replenish the fuel supply. You may simply demand to bleed an oil furnace line and first it upwards once again.
-
one
Turn the furnace off earlier starting whatsoever piece of work on the fuel pump. [i] Depending on your model, you may need to flip a switch nigh your furnace or plow it off at the breaker. You should also plough off the gas using the shut-off valve connected to the gas line.
-
2
Locate the drain screw on the fuel pump well-nigh where the fuel line comes in. The spiral is usually a small nipple-like screw.[2]
Advertisement
-
iii
Identify a modest bucket or pan under the bleed screw. The saucepan will take hold of any fuel that sputters out equally you bleed an oil furnace.[3]
- If the screw is in an area that is impossible to put a bucket or minor tray under, use a flexible tubing only big enough to fit over the bleed screw. Place the tube over the bleed screw and directly it to an area where you tin can fit the tray or bucket.
Advertisement
-
one
Use a small crescent wrench or pliers to slightly loosen the bleed screw. Brand certain the screw remains on the pump and is simply a picayune loose, so it doesn't fall completely off when you bleed the oil furnace.[4]
-
2
Button the reset button on the furnace to turn it back on. As the furnace starts to suck fuel in, air and fuel volition spit out of the drain spiral.[5]
- Keep your pliers or wrench on the screw ready to tighten it. This will besides ensure the screw remains in place, if you did loosen it too much.
- If the furnace bicycle ends before the air and fuel mixture stops sputtering, you'll need to push the reset push button again to continue the drain process until the furnace pushes out all the air from the line.
- Some furnaces may have a lockout system that won't allow y'all to reset more than one or 2 times. If this happens, you can override the lockout by belongings the reset button in until the furnace kicks in again.
-
3
Tighten the spiral equally soon as the air stops sputtering out and a steady stream of fuel pours out. Be conscientious non to tighten it too much. Replacing a stripped bleed spiral can be a very costly project.
-
4
Allow the furnace continue to run. It should run ordinarily without problems now. If it doesn't restart the next time, check the line for air again by repeating the drain process. Yous may not accept gotten all the air out the first time, or y'all may have a debris blockage in your fuel line.
Advert
Add New Question
-
Question
Part one, step one, says to plough off the furnace, just part two says to hit the reset push button. I accept to turn it back on right? What was the signal of turning it off?
Yes this is a error. Furnace should be on, and fuel is only pressurized when reset bicycle is activated.
-
Question
I have bled and pressed the reset push and it withal doesn't work. What should I do?
Information technology may take more time than expected. I only did this, and it took about eight reset/bleed cycles, and about 15 minutes. I had to look a minute or more earlier each reset. Each bleed was maybe 1/4 to 1/ii cup oil, plus air, so information technology filled two/3 of a large yogurt container. It was just starting to become frustrating when I heard the burner finally low-cal.
-
Question
How tight do I close the bleeder valve?
Johnny The Critic
Customs Answer
Tight enough so that oil doesn't leak out. Manus tight should be expert, and so but a smidgen more. Be very careful not to over tighten. A stripped bleeder valve will be a costly repair.
-
Question
Can I put the oil that I bled out back in the tank?
The statement for putting the oil back into the tank is so you don't take to dispose of it. Its value is insignificant, and so that is not a reason to do it. The argument against it is to avoid reintroducing the contamination and h2o that tends to accumulate in low parts of the tank and fuel lines. However, your fuel line filter volition catch particles that practise get reintroduced.
-
Question
My bleeder valve is stuck airtight. Do you have any suggestions on how to gratis it up?
Effort a deep socket or at the very least be certain to employ the exact size wrench (not adaptable). Counter-clockwise is usually to loosen. Of import not to strip bleeder every bit repair tin exist quite costly... Final chance would be vice grips only be very careful not to crush the valve.
-
Question
Can I put information technology back afterwards I bleed the furnace?
The bleeder valve must be tightened dorsum to its original position afterwards bleeding or the furnace volition not run properly. If not tightened it will more than than likely need to be bled again, very soon. Be very cautious not to over tighten.
-
Question
I have started the bleeding process, but no oil is coming through the haemorrhage valve. What could be incorrect?
Your line may be clogged and y'all may demand to accident it out with an air gun (bravado the air back into the tank). You may besides desire to changing the tank's filter while you are at it. It is adept to change the filter yearly.
-
Question
How many times tin can I striking reset later I bleed the line?
Johnny The Critic
Community Reply
Two times, await five-15 minutes before trying over again. If information technology doesn't restart hold the reset push for xxx seconds or then until it does restart, and so release (or power off the furnace at the power switch and retry). Bleed the line while restarting, until it flows solidly (no spurts) then tighten while its running and the furnace volition continue to run.
-
Question
I pushed the reset button and information technology still won't bleed or plow on. What do I do?
Check to be sure whatsoever power rubber switch for the burner circuit is switched on. Ensure you've got 120v ability at the burner. If not, observe the panel board circuit billow feeding the burner, information technology may demand to exist reset.
-
Question
It turns on and runs for 15 seconds, and so shuts off. Why?
That's normal. The oil primary (box with red switch) senses no flame and shuts down for safety.
Run into more answers
Ask a Question
200 characters left
Include your email accost to become a message when this question is answered.
Submit
Advert
Video
Thanks for submitting a tip for review!
Things Y'all'll Need
- Pliers or wrench
- Bucket
- Rubber gloves
About This Article
Thanks to all authors for creating a page that has been read 320,936 times.
Did this commodity help you?
Source: https://www.wikihow.com/Bleed-an-Oil-Furnace